Product Variations
- 66361 - Acoustic Foam
DESCRIPTION: Compressible sound protection foam for building assemblies (all 1 & 2 hr gypsum wallboard assemblies) in head-of-wall, wall-to-wall and bottom-of-wall joint applications both static and dynamic.
FEATURES:
DESCRIPTION: Flexible, precured dry intumescent strips used mainly for plastic & insulated pipe applications, wrapped simply around penetrating item(s) to completely fill annular space. In addition, for use with a universal collar for engineered plastic pipes 8 in. diameter and greater.
FEATURES:
PERFORMANCE: Tested in accordance with ASTM E814 (UL 1479); VOC compliant (CDPH Standard Method v1.2); complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops; tested by a third party independent laboratory to the ASTM G21 standard with Fungal Growth Rating results of zero
DESCRIPTION: Flexible, precured dry intumescent strips used for concrete & masonry floor & wall joints up to 2″ (51 mm) wide, duct insulation and up to 4″ PVC/CPVC & membrane penetrations.
FEATURES:
PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479) & ASTM E1966 (UL 2079); VOC compliant (CDPH Standard Method v1.2); complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops
DESCRIPTION: Precured dry intumescent strips and compressible foam used in head-of-wall, wall-to-wall and bottom-of-wall joint applications both static and dynamic.
FEATURES:
PERFORMANCE: UL Classified system up to 2 hrs in gypsum walls; tested in accordance with ASTM E1966 (UL 2079) and ASTM E90; L Rating < 1 CFM/LF; STC Rating 64; Compliant with the Buy America Act
DESCRIPTION: Moldable, non-curing, single-component, intumescent pliant in stick form for through-penetration systems.
FEATURES:
PERFORMANCE: UL Classified system up to 3 hrs; tested in accordance with ASTM E814 (UL 1479), ASTM E119 (UL 263); VOC compliant (CDPH Standard Method v1.2); tested by a third party independent laboratory to the ASTM G21 standard with Fungal Growth Rating results of zero; STC Rating 60